CERTIFICATIONS
MIL-STD 461
The military’s concern for EMI began with the installation of the first radio in a vehicle before World War I. However, since the application of radio technology and understanding its effects seem to parallel each other, it wasn’t until 1934 that the US Army Signal Corps published its first EMI standard: SCL-49, “Electrical Shielding and Radio Power Supply in Vehicles.” This document “protected” radio receivers by requiring vehicle operations to not “disturb” radio reception through shielding the ignition system, regulator, and generator.
As a result, the DoD formed a working group to consolidate and replace approximately 20 requirements into the initial MIL-STD 461 (the requirements), MIL-STD 462 (the measurement methodology), and MIL-STD 463 (definitions and acronyms) that were published in 1967. As with any general standard, especially the initial standard, revisions were required resulting in MIL-STD 461A being issued in August 1968. Although mandated, many programs made revisions and exceptions to the standard (even as 461 went from revision A to C). In 1993, the Tri-Service EMC Committee issued an updated MIL-STD 461 and MIL-STD 462, revision D. MIL-STD 463 was dropped and its definitions referenced to the American National Standards Institute (ANSI) C63.14 “Standard Dictionary for Technologies of Electromagnetic Compatibility (EMC), Electromagnetic Pulse (EMP) and Electrostatic Discharge (ESD)”. In 1999, 461 and 462 were combined, requirements updated and published in the currently enforced standard: MIL-STD 461E.
Applying MIL-STD 461E
C = Conducted
CExxx = Conducted emissions test
R = Radiated
RExxx = Radiated emissions test
E = Emission
CSxxx = ? Conducted susceptibility test
S = Susceptibility
RSxxx = Radiated susceptibility test
Requirement
Application
Frequency Range
Description
Changes From MIL-STD 461E
Conducted Emissions
CE101
Power & Interconnecting Leads
10kHz - 10MHz
NULL
No longer applicable to shipboard equip.
CE102
Power & Interconnecting Leads
No longer applicable to shipboard equip.
NULL
No longer applicable to shipboard equip.
CE106
Antenna Terminals
10kHz - 40GHz
NULL
NULL
Conducted Susceptibility
CS101
NULL
30Hz - 150kHz
The requirement is applicable to power input leads that obtain power from other sources not part of the computer including those that are rechargeable. There is no requirement on power output leads. This test ensures that performance is not degraded from the ripple voltages associated with generators, airborne, ship-borne, and vehicle-borne power sources.
Applicability and limits extended to 150kHz
CS103
Antenna Port , Intermodulation
15kHz - 10GHz
Not applicable to laptop, portable, or rack computers. (Applies only to receivers, transceivers, amplifiers, and the like.)
NULL
CS104
Antenna Port , Signal Rejection
30Hz - 20GHz
Not applicable to laptop, portable, or rack computers. (Applies only to receivers, transceivers, amplifiers, and the like.)
NULL
CS105
Antenna Port , Cross modulation
30Hz - 20GHz
Not applicable to laptop, portable, or rack computers. (Applies only to receivers, transceivers, amplifiers, and the like, which extract information from the amplitude modulation of a carrier.)
NULL
CS109
Structure current
60Hz - 100kHz
Not applicable to computers unless it is directly attached to very sensitive equipment (sensitive to 1�V or better) such as tuned receivers operating over the frequency range of the test.
Measurement procedures revised
CS114
Bulk Cable Injection
10kHz - 200MHz
The requirements are applicable to all electrical cables interfacing with the computer. It simulates currents that may be developed on the platform cabling from electromagnetic fields generated by antenna transmissions both on and off the platform.
Limits reduced to 200MHz
CS115
Bulk Cable Injection, Impulse Excitation
Transients - 2nS x 30nS
The requirements are applicable to all electrical cables interfacing with the computer. It simulates the fast rise and fall time transients that may be present due to platform switching operations and external transients such as lightning and electromagnetic pulses.
Applicability revised
CS116
Damped Sinusoid Transients - I/O & Power Cables
10kHz - 100MHz
The requirements are applicable to all electrical cables interfacing with the computer. It simulates electrical current and voltage waveforms occurring in platforms from excitation of natural resonance. In contrast to fast transients of CS115, this test uses dampened sine waveforms to simulate the occurrence on platforms resulting from lightning, electromagnetic pulses, and the electrical switching phenomena of the platform.
Measurement procedures & applicability revised
Radiated Emissions
RE101
Magnetic Field
30Hz - 100kHz
This is applicable to computers and is intended prim ari ly to control magnetic fields for applications where other equipment is sensitive to magnetic induction at lower frequencies. The most common example is a tuned receiver. (RS101 is a complementary requirement imposed on equipment to ensure compatibility with the anticipated magnetic fields.)
50cm requirement deleted; limits more stringent
RE102
Electric Field
10kHz - 18GHz
The requirements are applicable to electric field emissions from the computer and associated cables. The intent is to protect sensitive receivers from interference radiated from the computer and coupled through the antennas associated with the receiver (many receivers have sensitivities on the order of one microvolt).
Limits revised for subm ari ne equipment
RE103
Antenna Spurious & Harmonic Outputs
10kHz - 40GHz
Not applicable to computers, laptops, and notebooks.
NULL
Radiated Susceptibility
RS101
Magnetic Field
2MHz - 40GHz
NULL
Added use of mode-tuned reverberation chambers above 200MHz
RS103
Electric Field
10kHz - 18GHz
The requirements are applicable to electric field emissions from the computer and associated cables. The intent is to protect sensitive receivers from interference radiated from the computer and coupled through the antennas associated with the receiver (many receivers have sensitivities on the order of one microvolt).
Limits revised for subm ari ne equipment
RS105
Electromagnetic Pulse Field Transient
NULL
This requirement is primarily intended for computers that could be subject to the fast rise time, free-field, transient environment of an electromagnetic pulse (EMP). It applies only to those computer equipments and enclosures that are directly exposed to the incident field outside of the platform structure, or for equipment inside poorly shielded or unshielded platforms. This requirement is applicable only for EUT enclosures (electrical interface cabling should be protected in shielded conduit). Potential equipment responses due to cable coupling are controlled under CS116.
Limits revised for consistency with IEC Standards
This testing is not inexpensive. The five core tests (RS103, RE102, CS101, CS114 and CS116) will require roughly two days of lab time; the entire standard, seven to 10 days. These estimates assume there are no major redesigns.
Designing For MIL-STD 461 Tests
The display is another major gap where EMI can escape or affect the operation. All MIL-STD 461 tests require that the display of the information on the screen not flicker or be impaired during the test. Fortunately, there are several vendors that make a shielded glass that meet both the 461 and MIL-STD 810 requirements that can be mounted over the LED or LCD displays. Though costly, this method saves money by allowing manufacturers to use industrial COTS screens, while still complying with the stringent MIL-STD 461 standards.
The last area to address is the attached antenna or better known as printer, USB, Firewire, RS-232, and network cables. Common mode currents turn these cables into antennas that can pick up and conduct radiation through computer ports and impact the operation. This is why the RS103 susceptibility test requires all cables be connected to the unit during the test.
Conclusion
Military Standard (MIL-STD) certified solutions
ATEX Certification